velodyne_monitor#
Purpose#
This node monitors the status of Velodyne LiDARs. The result of the status is published as diagnostics.
Inner-workings / Algorithms#
The status of Velodyne LiDAR can be retrieved from http://[ip_address]/cgi/{info, settings, status, diag}.json
.
The types of abnormal status and corresponding diagnostics status are following.
Abnormal status | Diagnostic status |
---|---|
No abnormality | OK |
Top board temperature is too cold | ERROR |
Top board temperature is cold | WARN |
Top board temperature is too hot | ERROR |
Top board temperature is hot | WARN |
Bottom board temperature is too cold | ERROR |
Bottom board temperature is cold | WARN |
Bottom board temperature is too hot | ERROR |
Bottom board temperature is hot | WARN |
Rpm(Rotations per minute) of the motor is too low | ERROR |
Rpm(Rotations per minute) of the motor is low | WARN |
Connection error (cannot get Velodyne LiDAR status) | ERROR |
Inputs / Outputs#
Input#
None
Output#
Name | Type | Description |
---|---|---|
/diagnostics |
diagnostic_msgs/DiagnosticArray |
Diagnostics outputs |
Parameters#
Node Parameters#
Name | Type | Default Value | Description |
---|---|---|---|
timeout |
double | 0.5 | Timeout for HTTP request to get Velodyne LiDAR status [s] |
Core Parameters#
Name | Type | Default Value | Description |
---|---|---|---|
ip_address |
string | "192.168.1.201" | IP address of target Velodyne LiDAR |
temp_cold_warn |
double | -5.0 | If the temperature of Velodyne LiDAR is lower than this value, the diagnostics status becomes WARN [°C] |
temp_cold_error |
double | -10.0 | If the temperature of Velodyne LiDAR is lower than this value, the diagnostics status becomes ERROR [°C] |
temp_hot_warn |
double | 75.0 | If the temperature of Velodyne LiDAR is higher than this value, the diagnostics status becomes WARN [°C] |
temp_hot_error |
double | 80.0 | If the temperature of Velodyne LiDAR is higher than this value, the diagnostics status becomes ERROR [°C] |
rpm_ratio_warn |
double | 0.80 | If the rpm rate of the motor (= current rpm / default rpm) is lower than this value, the diagnostics status becomes WARN |
rpm_ratio_error |
double | 0.70 | If the rpm rate of the motor (= current rpm / default rpm) is lower than this value, the diagnostics status becomes ERROR |