Skip to content

ROS parameters#

CPU Monitor#

cpu_monitor:

Name Type Unit Default Notes
temp_warn float DegC 90.0 Generates warning when CPU temperature reaches a specified value or higher.
temp_error float DegC 95.0 Generates error when CPU temperature reaches a specified value or higher.
usage_warn float %(1e-2) 0.90 Generates warning when CPU usage reaches a specified value or higher.
usage_error float %(1e-2) 1.00 Generates error when CPU usage reaches a specified value or higher.
load1_warn float %(1e-2) 0.90 Generates warning when load average 1min reaches a specified value or higher.
load5_warn float %(1e-2) 0.80 Generates warning when load average 5min reaches a specified value or higher.
msr_reader_port int n/a 7634 Port number to connect to msr_reader.

HDD Monitor#

hdd_monitor:

  disks:

Name Type Unit Default Notes
name string n/a none The disk name to monitor temperature. (e.g. /dev/sda)
temp_error float DegC 55.0 Generates warning when HDD temperature reaches a specified value or higher.
temp_error float DegC 70.0 Generates error when HDD temperature reaches a specified value or higher.

hdd_monitor:

Name Type Unit Default Notes
hdd_reader_port int n/a 7635 Port number to connect to hdd_reader.
usage_warn float %(1e-2) 0.95 Generates warning when disk usage reaches a specified value or higher.
usage_error float %(1e-2) 0.99 Generates error when disk usage reaches a specified value or higher.

Memory Monitor#

mem_monitor:

Name Type Unit Default Notes
usage_warn float %(1e-2) 0.95 Generates warning when physical memory usage reaches a specified value or higher.
usage_error float %(1e-2) 0.99 Generates error when physical memory usage reaches a specified value or higher.

Net Monitor#

net_monitor:

Name Type Unit Default Notes
devices list[string] n/a none The name of network interface to monitor. (e.g. eth0, * for all network interfaces)
usage_warn float %(1e-2) 0.95 Generates warning when network usage reaches a specified value or higher.

NTP Monitor#

ntp_monitor:

Name Type Unit Default Notes
server string n/a ntp.ubuntu.com The name of NTP server to synchronize date and time. (e.g. ntp.nict.jp for Japan)
offset_warn float sec 0.1 Generates warning when NTP offset reaches a specified value or higher. (default is 100ms)
offset_error float sec 5.0 Generates warning when NTP offset reaches a specified value or higher. (default is 5sec)

Process Monitor#

process_monitor:

Name Type Unit Default Notes
num_of_procs int n/a 5 The number of processes to generate High-load Proc[0-9] and High-mem Proc[0-9].

GPU Monitor#

gpu_monitor:

Name Type Unit Default Notes
temp_warn float DegC 90.0 Generates warning when GPU temperature reaches a specified value or higher.
temp_error float DegC 95.0 Generates error when GPU temperature reaches a specified value or higher.
gpu_usage_warn float %(1e-2) 0.90 Generates warning when GPU usage reaches a specified value or higher.
gpu_usage_error float %(1e-2) 1.00 Generates error when GPU usage reaches a specified value or higher.
memory_usage_warn float %(1e-2) 0.90 Generates warning when GPU memory usage reaches a specified value or higher.
memory_usage_error float %(1e-2) 1.00 Generates error when GPU memory usage reaches a specified value or higher.
Back to top